Products content
N666024 | Component | 64 T | Storage | N666024A | Adaptor for MGI | 320 μL | -20°C. Avoid freeze/thaw cycle.
| N666024B | Index primer Mix (97-128) for MGI
| 32×12 μL | -20°C. Avoid freeze/thaw cycle.
|
|
Products Introduction This kit provides the Adaptor and Index primer Mix for MGI platform second generation sequencing, which is specially designed for MGI sequencing platform, the Adaptor is improved on the basis of the original MGI platform, the improved Adaptor is a universal type without Barcode sequence, which is convenient for automation, and it contains Universal primer and Index primer binding site, which is introduced into Barcode sequence by Index primer. It contains Universal primer and Index primer binding site, and the Barcode sequence is introduced by Index primer. The improved connector can significantly improve the library ligation efficiency, transformation efficiency and amplification efficiency. There are three sets of this kit, namely: Second Generation Sequencing Multi-sample Junction Primer Kit I (Barcode 1-48 of MGI platform), Second Generation Sequencing Multi-sample Junction Primer Kit II (Barcode 49-96 of MGI platform), and Second Generation Sequencing Multi-sample Junction Primer Kit III (Barcode 97-128 of MGI platform). These libraries cover Barcode 1-128 of MGI sequencing platform. The prepared libraries can be used for sequencing on BGISEQ-500RS (PE50/PE100/PE150), MGISEQ-2000RS (PE100/PE150), MGISEQ-200RS (PE100) and other sequencers of MGI platform. Provide your own instruments, reagents and consumables 1.Magnetic frame: DynaMagTM-2 is recommended. 2.DNA Purification and Recovery Kit: We recommend the use of the Kangwei Magnetic Bead Method DNA Purification and Recovery Kit. DNA Library Building Kit: Kangwei cfDNA Library Rapid Preparation Kit (MGI platform), DNA Library Rapid Preparation Kit, Second Generation Sequencing with Fragmentation Enzyme Rapid DNA Library Building Kit is recommended. 3.Anhydrous ethanol. 4.Reaction Tubes: It is recommended to use PCR tubes with low adsorption and 1.5 ml centrifuge tubes; Tips: It is recommended to use high-quality filter tips to prevent contamination of kits and libraries. Pre-experiment Preparation and Important Notes 1.Adaptor is a double-chain structure, please do not leave it above room temperature to avoid unchaining and affecting the use. 2.Please centrifuge the Index primer Mix briefly before uncapping so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers. workflow 
procedure The second-generation sequencing multi-sample junction primer kit II was used according to the DNA Library Rapid Preparation Kit (MGI platform) protocol. Index primer Mix is composed of Universal primer and Index primer, of which there are 32 Index primers. According to different mixing strategies, different Indexes can be added to each sample, or one set of Indexes can be added to each sample, and the final mixed library is required to ensure that all Indexes are assembled in a set. 8 of Indexes 97-128 are in a set, which are 97-104, 105-112, 113-120 and 121-128 respectively. Table: Barcode 97-128 for MGI 

|